Amana Error Code 4R: High Limit / Rollout
How to Fix Amana Code 4R
- Step 1: Turn off the furnace immediately at the breaker.
- Step 2: Ensure all vents are unblocked and clear of obstructions like snow or debris.
- Step 3: Replace the air filter with a clean one.
- Step 4: After 30 minutes, try to restart the furnace. If the error reappears, call a qualified HVAC technician for a thorough inspection and repair.
How to Reset Amana Code 4R
- Turn off the furnace power switch, usually located on or near the unit.
- Turn off the circuit breaker for the furnace. Wait 30 seconds.
- Restore power at the breaker and flip the furnace switch back on.
- Set the thermostat to call for heat. If the error code returns after 2-3 ignition attempts, the fault requires repair.
Resetting clears the code from the display but does not fix the underlying fault. If the code returns after reset, proceed to the diagnostic steps above.
What Does Amana Error Code 4R Mean?
The '4R' error code on your Amana furnace indicates a high limit or rollout switch has tripped. These are safety devices designed to shut down the furnace if it overheats or if flames are detected where they shouldn't be. The high limit switch monitors the temperature inside the furnace heat exchanger, and the rollout switch detects flames outside the combustion chamber. When either of these switches trips, it means your furnace is experiencing a dangerous condition. Continuing to run the furnace could lead to a fire, damage to the unit, or carbon monoxide poisoning. It's important to address this issue immediately to ensure your safety and prevent further damage.
Common Causes
- Dirty air filter restricting airflow, causing the furnace to overheat.
- Blocked vent or flue pipe preventing exhaust gases from escaping properly.
- Faulty blower motor not moving enough air across the heat exchanger.
- Overfiring furnace due to a gas valve malfunction.
- Cracked heat exchanger allowing flames to escape.
Diagnostic Steps
| If... | Check | Expected |
|---|---|---|
| Furnace is locked out with 4R error | Check continuity of the high limit switch | Closed (0 ohms) when cool, open (OL) when tripped |
| High limit switch is open | Check continuity of rollout switches | Closed (0 ohms) when cool, open (OL) when tripped |
| Rollout switch is open | Inspect for signs of flame rollout (sooting, melted wires) | No visible signs of flame rollout |
| No tripped switches found | Measure voltage to gas valve during call for heat | 24VAC |
Applicable Amana Models
Replacement Parts
| Part | OEM Number | Est. Cost | Where to Buy |
|---|---|---|---|
| High Limit Switch | A13711-26 | — | Find Part |
| Rollout Switch | A13711-30 | — | Find Part |
| Blower Motor | — | — | — |
Related Codes on Same Models
Other codes that affect the same Amana model families as 4R.
| Code | Description | Severity |
|---|---|---|
| 10R | Communication Error | Warning |
| 1R | Flame Without Call | Critical |
| 2R | Pressure Switch Stuck Closed | Warning |
| 3R | Pressure Switch Open | Warning |
| 5R | Ignition Lockout | Critical |
| 6R | Gas Valve Relay Fault | Critical |
| 7R | Low Flame Signal | Critical |
| 8R | Reversed Polarity | Critical |
| 9R | Blower Motor Fault | Warning |