Carrier Error Code 32: Low Flame Sense

Severity
Warning
Type
led blink pattern
Where to look
sight glass
Estimated repair cost: $75 — $200 (parts + labor)
Warning: Your Carrier furnace isn't sensing a flame, which has caused it to shut down for safety. You'll likely need a technician to diagnose and fix the problem.

How to Fix Carrier Code 32

  1. Step 1: Check your furnace filter. A dirty filter restricts airflow, which can affect the burner flame. Replace it if needed.
  2. Step 2: Ensure the furnace's gas supply is turned on. Check the shut-off valve near the furnace and the main gas supply to your home.
  3. Step 3: Reset the furnace by turning off the power at the breaker for a minute, then turning it back on. If the error persists, call a qualified HVAC technician.

How to Reset Carrier Code 32

  1. Turn off the furnace power switch, usually located on or near the unit.
  2. Turn off the circuit breaker for the furnace. Wait 30 seconds.
  3. Restore power at the breaker and flip the furnace switch back on.
  4. Set the thermostat to call for heat. If the error code returns after 2-3 ignition attempts, the fault requires repair.

What does 32 mean?

The Carrier error code 32, or a blinking LED pattern indicating 'Low Flame Sense,' means the furnace's control board isn't detecting a stable flame after ignition. The furnace goes through its normal start-up sequence, the gas valve opens, and the burners light. However, the flame sensor, a small metallic rod in the flame, isn't sending a strong enough signal back to the control board to confirm the flame is present. Because the furnace cannot reliably verify the flame, it shuts down as a safety precaution.

This issue can stem from a few different problems, ranging from a dirty flame sensor to a more serious gas supply issue. Because gas furnaces are involved, it's important to address this issue promptly to ensure safe and reliable heating.

Affected Models

Replacement Parts

PartOEM NumberEst. Cost
Flame Sensor KH42LZ010
Gas Valve EF32CW225
Ignition Control Module

Related Codes on Same Models

CodeDescriptionSeverity
11 No Previous Error Info
12 Blower On After Power Up Warning
13 Limit/Rollout Fault Critical
14 Ignition Lockout Critical
21 Gas Heating Lockout Critical
22 Abnormal Flame Critical
23 Pressure Switch Fault Warning
24 Secondary Voltage Fuse Warning
31 High Stage Pressure Fault Warning
33 Limit/Rollout Switch Lockout Critical