Rheem Error Code A061: Fan Speed Error
Warning: Your Rheem HVAC system has encountered a fan speed error. It's safe to use, but needs professional attention.
How to Fix Rheem Code A061
- Check if the fan is running at all. If not, try resetting the system by turning off the power at the thermostat and the main panel, then turning it back on after 30 seconds.
- Inspect the fan control board for any visible damage or signs of overheating. If you're not comfortable doing this, it's best to call a professional.
- When to call a pro: Always if you suspect an electrical issue, or if the fan still isn't working after a reset.
How to Reset Rheem Code A061
- Turn off the unit using the power button on the front panel.
- Turn off the gas supply valve.
- Turn off the circuit breaker supplying power to the unit. Wait 30 seconds.
- Restore power at the breaker, then open the gas valve.
- Turn the unit back on. If the error returns, the underlying issue needs repair.
What does A061 mean?
The Rheem A061 error code indicates that your HVAC system's fan isn't operating at the correct speed. This could be due to a faulty fan control board, a problem with the fan motor itself, or an issue with the system's wiring. The fan may run too fast, too slow, or not at all. While the system is still functional, it's important to address this issue to maintain optimal performance and prevent further damage.
Affected Models
- R92V
- R92V
- R92E
- R92E
- R92E
- Rheem Classic Plus Series
- Rheem Classic Plus Series
- Rheem Classic 90 Plus
- Rheem Classic 80 Plus
- Rheem Prestige Series
- Rheem Classic Series
- Rheem Prestige Series
- Rheem Classic Series
- Rheem Classic Plus Series
- Rheem Classic Plus Series
- Rheem Prestige
- Rheem Classic
- Rheem Prestige Series
- Rheem Classic Series
- NCB
- NPE
- RNC
- RNG
- RNE
- Rheem Classic Series
- Rheem Classic Plus Series
- RNC
- RPB
- Rheem Prestige Series
- Rheem Classic Series
- RNC
- R801T
- R801T
- RH2T
- RP16
- RP16
- RTGH
- RGE
- Rheem Classic Plus Series
- Rheem Classic Plus Series
- Rheem Classic Series
- Rheem Classic Series
- Rheem Classic Plus Series
- Rheem Prestige Series
- Rheem Classic 80% Gas Furnace
- Rheem Prestige 95% Gas Furnace
- R92V
Replacement Parts
| Part | OEM Number | Est. Cost |
|---|---|---|
| Fan control board | RHEEM 340120 | — |
| Fan motor | RHEEM 340130 | — |
Related Codes on Same Models
| Code | Description | Severity |
|---|---|---|
| A001 | Ignition Failure | Warning |
| A003 | Abnormal Ignition | Warning |
| A004 | False Flame Detection | Warning |
| A008 | Exhaust Temperature High | Warning |
| A011 | No Flame Detected | Warning |
| A021 | Over-Temperature | Warning |
| A031 | Inlet Thermistor Open/Short | Warning |
| A041 | Outlet Thermistor Open/Short | Warning |
| A043 | Water Level Error | Warning |
| A051 | Fan Motor Abnormality | Warning |