Rheem Error Code 10: Rheem Code 10 - Air Supply or Exhaust Blockage
Warning: Your Rheem tankless water heater has detected a blocked air intake or exhaust vent. The unit will not operate until airflow is restored.
How to Fix Rheem Code 10
- Step 1: Go outside and visually inspect the exhaust vent terminal. Remove any visible debris, bird nests, leaves, or ice buildup.
- Step 2: Check that nothing is placed against or blocking the air intake on the unit.
- Step 3: If you have a condensate drain line, make sure it is not frozen or kinked.
- Step 4: Power-cycle the unit by turning it off, waiting 30 seconds, and turning it back on.
- Step 5: If the error returns after clearing the vent, call a licensed technician to inspect the full vent run.
How to Reset Rheem Code 10
- Turn off the unit using the power button on the front panel.
- Turn off the gas supply valve.
- Turn off the circuit breaker supplying power to the unit. Wait 30 seconds.
- Restore power at the breaker, then open the gas valve.
- Turn the unit back on. If the error returns, the underlying issue needs repair.
What does 10 mean?
Indicates blocked air intake or exhaust venting. The unit detects insufficient combustion air supply or restricted exhaust gas flow.
Affected Models
- R92V
- R92V
- R92E
- R92E
- R92E
- Rheem Classic Plus Series
- Rheem Classic Plus Series
- Rheem Classic 90 Plus
- Rheem Classic 80 Plus
- Rheem Prestige Series
- Rheem Classic Series
- Rheem Prestige Series
- Rheem Classic Series
- Rheem Classic Plus Series
- Rheem Classic Plus Series
- Rheem Prestige
- Rheem Classic
- Rheem Prestige Series
- Rheem Classic Series
- NCB
- NPE
- RNC
- RNG
- RNE
- Rheem Classic Series
- Rheem Classic Plus Series
- RNC
- RPB
- Rheem Prestige Series
- Rheem Classic Series
- RNC
- R801T
- R801T
- RH2T
- RP16
- RP16
- RTGH
- RGE
- Rheem Classic Plus Series
- Rheem Classic Plus Series
- Rheem Classic Series
- Rheem Classic Series
- Rheem Classic Plus Series
- Rheem Prestige Series
- Rheem Classic 80% Gas Furnace
- Rheem Prestige 95% Gas Furnace
- R92V
Replacement Parts
| Part | OEM Number | Est. Cost |
|---|---|---|
| Combustion Fan Motor | SP20875 | — |
| Air Intake Filter | SP20127 | — |
| Exhaust Vent Terminal | — | — |
Related Codes on Same Models
| Code | Description | Severity |
|---|---|---|
| A001 | Ignition Failure | Warning |
| A003 | Abnormal Ignition | Warning |
| A004 | False Flame Detection | Warning |
| A008 | Exhaust Temperature High | Warning |
| A011 | No Flame Detected | Warning |
| A021 | Over-Temperature | Warning |
| A031 | Inlet Thermistor Open/Short | Warning |
| A041 | Outlet Thermistor Open/Short | Warning |
| A043 | Water Level Error | Warning |
| A051 | Fan Motor Abnormality | Warning |