Ruud Error Code 16: Outlet Temp Sensor Fault

Severity
Warning
Type
digital display
Estimated repair cost: $100 — $250 (parts + labor)
Warning: Your Ruud tankless water heater has detected a problem with its outlet temperature sensor and has shut down to prevent potential issues. You will have no hot water until this is resolved.

How to Fix Ruud Code 16

  1. Step 1: Power cycle the unit by turning off the breaker for 30 seconds, then turn it back on. This may reset a temporary error.
  2. Step 2: Check the wiring connections on the outside of the unit for any obvious signs of damage or corrosion. Do not open the unit.
  3. Step 3: If the error persists after power cycling, contact a qualified HVAC technician to diagnose and repair the issue.

How to Reset Ruud Code 16

  1. Turn off the furnace power switch, usually located on or near the unit.
  2. Turn off the circuit breaker for the furnace. Wait 30 seconds.
  3. Restore power at the breaker and flip the furnace switch back on.
  4. Set the thermostat to call for heat. If the error code returns after 2-3 ignition attempts, the fault requires repair.

Resetting clears the code from the display but does not fix the underlying fault. If the code returns after reset, proceed to the diagnostic steps above.

What Does Ruud Error Code 16 Mean?

The 'Outlet Temp Sensor Fault' (Error Code 16) on your Ruud tankless water heater indicates that the control board isn't receiving a valid signal from the temperature sensor located at the outlet of the unit. This sensor is responsible for monitoring the hot water temperature as it leaves the heater. The control board uses this information to modulate the burner and maintain a consistent output temperature. When the control board detects a fault—either a short, open circuit, or an out-of-range reading—it triggers this error and shuts down the unit. This is a safety measure to prevent overheating or delivering water at an unsafe temperature. It's important to address this issue promptly to restore hot water service and ensure the water heater operates safely and efficiently. Because the unit is locked out, you will not have hot water until the issue is resolved.

Common Causes

  • Faulty outlet temperature sensor
  • Loose or corroded wiring connections to the sensor or control board
  • Damaged wiring harness leading to the sensor
  • Defective control board

Diagnostic Steps

If... Check Expected
Unit displays error code 16 Measure the resistance of the outlet temperature sensor at the control board connector. Disconnect the sensor before measuring. Resistance should be within the range specified in the Ruud service manual for the given temperature (typically around 10-20k ohms at room temperature).
Sensor resistance is out of range Inspect the wiring harness and connector for damage or corrosion. Wiring and connector are in good condition.
Wiring and connector are good, but sensor resistance is still out of range Replace the outlet temperature sensor. Error code resolves after replacement.
Error persists after replacing the sensor Check the voltage at the control board connector for the sensor. Consult the service manual for the correct voltage. Correct voltage is present, indicating a possible control board issue.

Applicable Ruud Models

Replacement Parts

Part OEM Number Est. Cost Where to Buy
Outlet Temperature Sensor SP20364
Control Board

Related Codes on Same Models

Other codes that affect the same Ruud model families as 16.

Code Description Severity
11 No Ignition Critical
12 Flame Failure Critical
13 Improper Combustion Critical
14 Overheat / Thermal Fuse Critical
15 Inlet Temp Sensor Fault Warning
21 Air Supply / Operational Switch Warning
24 Flow Sensor Malfunction Warning
29 Condensate Neutralizer Issue Warning
31 Inlet Water Filter Warning
33 Fan Motor Fault Warning