Warning: The indoor coil temperature sensor has failed or become disconnected, preventing the unit from properly regulating temperature. This will likely result in the unit not cooling or heating effectively.
How to Fix Fujitsu Code E4:00
Step 1: Turn the unit off and then back on. Sometimes a temporary glitch can trigger the error code. Wait a few minutes after turning it off before turning it back on.
Step 2: Check the area around the indoor unit for any obvious obstructions blocking airflow. Make sure the air filter is clean.
Step 3: If the error persists after restarting the unit, contact a qualified HVAC technician to diagnose and repair the problem.
How to Reset Fujitsu Code E4:00
Turn off the unit using the remote control or wall controller.
Turn off the circuit breaker for the outdoor and indoor units. Wait 60 seconds.
Restore power at the breaker.
Turn the unit on with the remote control. If the error returns, the fault needs professional diagnosis.
What does E4:00 mean?
The Fujitsu E4:00 error code indicates an open circuit in the indoor coil temperature sensor. This sensor, also called a thermistor, is responsible for measuring the temperature of the indoor coil (the part that gets cold when cooling or hot when heating). The sensor sends this temperature information back to the unit's control board, which uses it to regulate the cooling or heating process. An 'open' circuit means the electrical connection is broken, so the control board isn't receiving any temperature data. Because the control board doesn't know the coil temperature, the unit will likely stop operating or run inefficiently to protect itself from damage (like freezing the coil). This prevents the unit from properly heating or cooling your space.