Navien Error Code E046: Outlet Thermistor Open/Short

Severity
Warning
Type
digital display
Where to look
front panel
Estimated repair cost: $100 — $250 (parts + labor)
Warning: Your Navien boiler or combi unit has locked out due to a faulty outlet thermistor, which can cause inaccurate temperature readings but does not pose an immediate safety risk.

How to Fix Navien Code E046

  1. Step 1: Turn off power to the Navien unit at the wall switch or breaker. Wait 30 seconds, then turn it back on. If the error clears, it was a temporary glitch.
  2. Step 2: Check that the unit's front panel is properly closed and all wire connections inside are snug. Do not remove the panel if you are not comfortable.
  3. Step 3: If the error returns, call a Navien-qualified technician. They will need to test the thermistor resistance and likely replace it.

How to Reset Navien Code E046

  1. Turn off the unit using the power button on the front panel.
  2. Turn off the gas supply valve.
  3. Turn off the circuit breaker supplying power to the unit. Wait 30 seconds.
  4. Restore power at the breaker, then open the gas valve.
  5. Turn the unit back on. If the error returns, the underlying issue needs repair.

Resetting clears the code from the display but does not fix the underlying fault. If the code returns after reset, proceed to the diagnostic steps above.

What Does Navien Error Code E046 Mean?

The E046 code on your Navien unit means the outlet thermistor, a temperature sensor located on the hot water outlet pipe, is either open (infinite resistance) or shorted (near-zero resistance). This sensor tells the control board how hot the water leaving the heat exchanger is. When it fails, the board can't regulate the burner properly, so it shuts down the system to prevent overheating or damage. This is a common issue on Navien combi boilers and water heaters, especially after several years of use. For a homeowner, you'll likely see this error after the unit runs for a minute or two and then stops. The display will flash E046, and the unit will not heat water or run the central heating until it's fixed. The thermistor is a sensor mounted on the outlet pipe, often behind the front panel. While no gas or water leaks are associated with this code, you need a professional to replace the sensor to get your system back online. The fix requires removing the front cover, unclipping the sensor from the pipe, and installing a new one. Most homeowners should call a pro, but if you're handy, you can buy the right thermistor from a Navien supplier. Just be aware that mishandling the wiring can cause other issues.

Common Causes

  • Thermistor sensor has failed due to age or thermal cycling fatigue
  • Loose or corroded wire connection at the thermistor harness plug
  • Damaged wiring between the thermistor and the main control board
  • Control board failure that misreads the thermistor signal (rare)

Diagnostic Steps

If... Check Expected
Error E046 appears and stays on after power cycle Disconnect the outlet thermistor harness from the control board. Measure resistance across the thermistor wires with a multimeter set to ohms. Between 10,000 and 50,000 ohms at room temperature (approx. 77°F). Open circuit (OL) or short (0 ohms) indicates a bad sensor.
Thermistor resistance is within range Inspect the harness connector for bent pins, corrosion, or broken wires. Check continuity back to the control board. Solid connection with less than 1 ohm resistance in each wire. No intermittent breaks.
All wiring and thermistor check out Use a known-good thermistor from another identical Navien unit (if available) or test the control board output voltage at the thermistor pins. Control board should supply 5 VDC between the signal and ground pins. If not, board may be faulty.

Applicable Navien Models

Source Documentation

Referenced in 6 official Navien technical manuals.

ManualPageReasonAction
NFB-H Installation & Operation Manual116Heat Exchanger ThermistorCheck thermistor connector.
Navien NCB-H Installation & Operation Manual129Heat Exchanger ThermistorContact technical support at 1-800-519-8794.
Navien NFB-H Installation & Operation Manual116Heat Exchanger ThermistorCheck thermistor connector.
Navien NFC-H Installation & Operation Manual127Abnormal operation: heat exchanger overheating sensorAuto RESET
Navien NHB-H Installation & Operation Manual119Heat Exchanger ThermistorCheck thermistor connector.
Navien NPF Installation & Operation Manual125Abnormal limit control operation on the heat exchangerThis error occurs when the limit control on the heat exchanger does not operate properly. ● Stop operating the furnace and contact Technical Support at 1-800-519-8794.

Replacement Parts

Part OEM Number Est. Cost Where to Buy
Outlet Thermistor (NTC sensor) 30019717A
Inlet Thermistor (if misdiagnosed) 30019718A
Control Board (PCB)

Related Codes on Same Models

Other codes that affect the same Navien model families as E046.

Code Description Severity
E001 Ignition Failure Warning
E003 Abnormal Ignition Warning
E004 False Flame Detection Warning
E012 Flame Loss Warning
E031 Inlet Thermistor Open/Short Warning
E110 Exhaust Blocked Warning
E205 Water Flow Sensor Failure Warning
E517 Water Flow Switch Failure Warning
E736 CH Return Thermistor Failure Warning
E740 CH Buffer Tank Thermistor Warning