Navien Error Code E784: Outdoor Temp Sensor Failure

Severity
Warning
Type
digital display
Where to look
front panel
Estimated repair cost: $100 — $250 (parts + labor)
Warning: Your Navien boiler has detected a problem with the outdoor temperature sensor and has shut down to prevent damage. Call a professional for repair.

How to Fix Navien Code E784

  1. Step 1: Check if the outdoor temperature sensor is clean and free of debris. If not, gently clean it.
  2. Step 2: Inspect the wiring between the sensor and the boiler for any signs of damage or corrosion. If you find any issues, do not attempt to repair them yourself.
  3. Step 3: If the sensor and wiring appear to be in good condition, it's best to call a professional HVAC technician for further diagnosis and repair.

How to Reset Navien Code E784

  1. Turn off the unit using the power button on the front panel.
  2. Turn off the gas supply valve.
  3. Turn off the circuit breaker supplying power to the unit. Wait 30 seconds.
  4. Restore power at the breaker, then open the gas valve.
  5. Turn the unit back on. If the error returns, the underlying issue needs repair.

What does E784 mean?

The E784 error on your Navien boiler indicates a failure in the outdoor temperature sensor. This sensor is crucial for your boiler's operation, as it helps regulate the water temperature based on the outdoor climate. When this sensor fails, your boiler can't accurately adjust its operation, leading to system lockouts and potential damage. The most common cause for this error is a faulty sensor, but it could also be due to a wiring issue or a problem with the boiler's control board.

Affected Models

Source Documentation

ManualPageReasonAction
NFB-H Installation & Operation Manual 116 Zone Controller Communication Check wiring and settings.
Navien NCB-H Installation & Operation Manual 130 Zone Controller Communication Contact technical support at 1-800-519-8794.
Navien NFB-H Installation & Operation Manual 116 Zone Controller Communication Check wiring and settings.
Navien NFC-H Installation & Operation Manual 128 Abnormal operation: zone controller communication (external device) Alarm
Navien NHB-H Installation & Operation Manual 119 Zone Controller Communication Check wiring and settings.

Replacement Parts

PartOEM NumberEst. Cost
Outdoor Temperature Sensor 300-0000-0000

Related Codes on Same Models

CodeDescriptionSeverity
E001 Ignition Failure Warning
E003 Abnormal Ignition Warning
E004 False Flame Detection Warning
E012 Flame Loss Warning
E016 Overheating Warning
E030 Exhaust Overheat Sensor Warning
E031 Inlet Thermistor Open/Short Warning
E046 Outlet Thermistor Open/Short Warning
E047 DHW Thermistor Open/Short Warning
E060 Fan Motor Abnormality Warning