Goodman Error Code CONTINUOUS: Reversed Polarity

Severity
Warning
Type
led blink count
Where to look
sight glass
Estimated repair cost: $300 — $650 (parts + labor)
Warning: Your Goodman HVAC system has detected a reversed polarity issue, which could damage components and cause system failure. Turn off power to the unit immediately and call a professional.

LED Blink Pattern

How to Fix Goodman Code CONTINUOUS

  1. Step 1: Turn off power to the HVAC unit at the main electrical panel
  2. Step 2: Do not attempt to fix this issue yourself. Call a licensed HVAC technician.

How to Reset Goodman Code CONTINUOUS

  1. Turn off the furnace power switch, usually located on or near the unit.
  2. Turn off the circuit breaker for the furnace. Wait 30 seconds.
  3. Restore power at the breaker and flip the furnace switch back on.
  4. Set the thermostat to call for heat. If the error code returns after 2-3 ignition attempts, the fault requires repair.

Resetting clears the code from the display but does not fix the underlying fault. If the code returns after reset, proceed to the diagnostic steps above.

What Does Goodman Error Code CONTINUOUS Mean?

The CONTINUOUS error code on your Goodman HVAC system indicates that there's a reversed polarity issue. This means that the positive and negative wires have been swapped, which can cause excessive current flow and heat, potentially damaging components. While this isn't an immediate safety risk like a gas leak, it's crucial to address this issue promptly to prevent further damage and system failure.

Common Causes

  • Reversed polarity at the main electrical panel
  • Swapped wires at the HVAC unit's electrical connection
  • Improperly wired control board or other electrical components

Diagnostic Steps

If... Check Expected
HVAC unit is not running Measure voltage at the control board's power terminals 120V AC (or 240V AC for some models)
Voltage is present Inspect wiring at the main electrical panel and HVAC unit Correct polarity (black wire to L1/L2, white wire to L3/N)

Applicable Goodman Models

Recall Notices

Goodman/Daikin Evaporator Coil Drain Pans Recalled Due to Fire Hazard 22-014 Active

Issued: November 1, 2021

Affected models: Molded plastic evaporator coil drain pans in up-flow condensing gas furnaces

Drain pans can overheat, melt, and deform, posing a fire hazard. Recall expanded January 2024.

View official notice

Replacement Parts

Part OEM Number Est. Cost Where to Buy
Control Board C025123
Fuse F001234

Related Codes on Same Models

Other codes that affect the same Goodman model families as CONTINUOUS.

Code Description Severity
1 System Lockout Warning
2 Pressure Switch Stuck Closed Warning
3 Pressure Switch Stuck Open Warning
4 Open High Limit Switch Warning
5 Flame Sensed With Gas Valve Off Warning
6 Open Rollout Switch Warning
7 Low Flame Signal Warning
8 Ignitor Error Warning
F01 Goodman Code F01 - Ignition Lockout Critical
STEADY-ON Normal Operation Info