Goodman Error Code STEADY-ON: Normal Operation
LED Blink Pattern
How to Fix Goodman Code STEADY-ON
- Check your thermostat settings and ensure the fan is set to 'AUTO'
- Replace your air filter if it's dirty
- If the issue persists, try turning off your HVAC system at the circuit breaker for 30 seconds, then turn it back on
How to Reset Goodman Code STEADY-ON
- Turn off the furnace power switch, usually located on or near the unit.
- Turn off the circuit breaker for the furnace. Wait 30 seconds.
- Restore power at the breaker and flip the furnace switch back on.
- Set the thermostat to call for heat. If the error code returns after 2-3 ignition attempts, the fault requires repair.
Resetting clears the code from the display but does not fix the underlying fault. If the code returns after reset, proceed to the diagnostic steps above.
What Does Goodman Error Code STEADY-ON Mean?
The STEADY-ON error code on your Goodman HVAC system indicates that the unit has been running continuously for an extended period. This is not a critical error, but it's important to address to prevent excessive energy usage and potential system damage. The most common causes for this code are incorrect thermostat settings or a system issue that's preventing the unit from cycling off.
Common Causes
- Incorrect thermostat settings, such as the fan set to 'ON' instead of 'AUTO'
- A system issue preventing the unit from reaching its setpoint temperature
- Dirty air filter restricting airflow
- Faulty thermostat or control board
Diagnostic Steps
| If... | Check | Expected |
|---|---|---|
| Thermostat is set to 'AUTO' and temperature is set correctly | Measure the temperature at the thermostat and compare it to the room temperature | A difference of no more than 2°F (1.1°C) |
| Air filter is clean | Inspect the outdoor unit for any signs of damage or obstruction | No visible damage or obstructions |
Applicable Goodman Models
Recall Notices
Issued: November 1, 2021
Affected models: Molded plastic evaporator coil drain pans in up-flow condensing gas furnaces
Drain pans can overheat, melt, and deform, posing a fire hazard. Recall expanded January 2024.
Replacement Parts
| Part | OEM Number | Est. Cost | Where to Buy |
|---|---|---|---|
| Thermostat | — | — | — |
| Control Board | C1200-1200 | — | Find Part |
Related Codes on Same Models
Other codes that affect the same Goodman model families as STEADY-ON.
| Code | Description | Severity |
|---|---|---|
| 1 | System Lockout | Warning |
| 2 | Pressure Switch Stuck Closed | Warning |
| 3 | Pressure Switch Stuck Open | Warning |
| 4 | Open High Limit Switch | Warning |
| 5 | Flame Sensed With Gas Valve Off | Warning |
| 6 | Open Rollout Switch | Warning |
| 7 | Low Flame Signal | Warning |
| 8 | Ignitor Error | Warning |
| CONTINUOUS | Reversed Polarity | Warning |
| F01 | Goodman Code F01 - Ignition Lockout | Critical |