Search Error Codes

Search across 21 brands and 300+ diagnostic codes

37 results for "ignition"

E003
Navien Abnormal Ignition

The E003 error on your Navien boiler indicates that the ignition system isn't functioning as it should. This could be du...

14
Carrier Ignition Lockout

The Carrier error code 14, also known as an ignition lockout, means your furnace tried to ignite the burners multiple ti...

21
Carrier Gas Heating Lockout

The Carrier 21 error code, also known as a gas heating lockout, signals that your furnace has tried to ignite the gas mu...

72
Noritz Flame Rod/Gas Valve Issue

Noritz error code 72 indicates a problem with either the flame rod or gas valve in your water heater. The flame rod dete...

A099
Rheem PCB Failure

The A099 error on Rheem systems indicates a failure of the main control board (PCB). This board controls all system func...

1
Lennox Ignition Failure

The error code 1 on your Lennox HVAC system indicates that the ignition system has failed to ignite the burner. This cou...

90
Noritz Combustion Abnormality

Error code 90 on your Noritz water heater indicates a combustion abnormality. This could be due to improper gas supply, ...

A001
Rheem Ignition Failure

The A001 error code on your Rheem HVAC system indicates that the ignition system isn't functioning correctly. This could...

A003
Rheem Abnormal Ignition

The A003 error on your Rheem HVAC system indicates an abnormal ignition issue. This could mean that the system is having...

32
Carrier Low Flame Sense

The Carrier error code 32, or a blinking LED pattern indicating 'Low Flame Sense,' means the furnace's control board isn...

34
Carrier Ignition/Flame Sense Fault

Error code 34 on a Carrier furnace indicates an ignition or flame sensing issue. The control board isn't detecting a sta...

7
Goodman Low Flame Signal

The Goodman 7 error code indicates that your furnace's flame sensor isn't detecting a strong enough flame from the burne...

5
Lennox Flame Rollout Switch Open

The Flame Rollout Switch Open error code (5) on your Lennox heating system indicates that the switch designed to prevent...

7
Lennox Ignition Lockout

Lennox error code 7, or ignition lockout, means your heating system has temporarily shut down to prevent damage. This co...

E001
Navien Ignition Failure

Error code E001 on a Navien unit means the ignition control module tried to light the burner but didn't detect a flame w...

E012
Navien Flame Loss

The E012 error on your Navien boiler indicates a flame loss issue. This could be due to a problem with the ignition syst...

11
Noritz Ignition Failure

The Noritz 11 error code indicates that your water heater's ignition system is not functioning properly. This could be d...

11
Rinnai No Ignition

Error code 11 on your Rinnai water heater indicates a 'No Ignition' issue. This means the burner isn't firing up to heat...

12
Rinnai Flame Failure

The Rinnai 12 error code indicates that your water heater's flame has gone out, preventing it from heating water. This c...

72
Rinnai Flame Rod Detection

The Rinnai 72 error code indicates a problem with the flame rod, a crucial safety component in your water heater. The fl...

E351
Honeywell Equipment Fault

The Honeywell E351 error code indicates a general equipment fault within your HVAC system. This is a broad error, meanin...

E06
A.O. Smith Flammable Vapor Detection

The E06 error code on your A.O. Smith water heater indicates that the unit's flammable vapor sensor has detected the pre...

5R
Amana Ignition Lockout

The '5R' error code on your Amana furnace indicates an 'Ignition Lockout'. This means the furnace tried several times to...

F13
Bradford White Ignition Failure

The F13 error code on your Bradford White tankless water heater means the unit tried to light the burner but failed. Thi...

11
Richmond No Ignition

Error code 11 on your Richmond water heater means the unit tried to start but failed to light the burner. This usually h...

12
Richmond Flame Failure

Error code 12, 'Flame Failure,' on your Richmond water heater means the unit tried to light the burner, but the flame wa...

11
Ruud No Ignition

The Ruud '11' error code signals that the furnace attempted to ignite the gas multiple times but failed. This usually me...

111
Takagi Ignition Failure

Error code 111 on your Takagi tankless water heater signifies an ignition failure. This means the unit tried to start th...

710
Takagi PCB Fault

The Takagi 710 error code indicates a fault within the Printed Circuit Board (PCB), which is the main control board of y...

760
Takagi Communication Error

The Takagi error code 760 indicates a communication problem within the unit's electronic components. Essentially, the di...

R3
York Pressure Switch Stuck Open

The R3 error code on your York furnace indicates that the pressure switch is stuck in the open position. This switch is ...

R7
York Ignition Lockout

The R7 error code on your York furnace indicates an 'Ignition Lockout'. This means the furnace attempted to ignite the b...

7R
Amana Low Flame Signal

The '7R' error code on your Amana furnace indicates a low or unstable flame signal. This means the furnace control board...

9H
Goodman Goodman Code 9H - Soft Lockout

The 9H error code on your Goodman furnace indicates a 'soft lockout.' This happens when the furnace attempts to ignite, ...

F01
Goodman Goodman Code F01 - Ignition Lockout

The F01 error code on your Goodman furnace indicates an 'Ignition Lockout'. This means the furnace attempted to light th...

55
Rinnai Rinnai Code 55 - False Fire Detection

Rinnai error code 55 indicates that the unit's flame sensor is detecting a flame when it shouldn't be. This can happen e...

11
Rheem Rheem Code 11 - No Ignition

Rheem error code 11 signals that your tankless water heater attempted to ignite the burner but failed. This means the un...